Chemistry Analyzers

Photometer DTN-510K
Photometer DTN 510k
  • Color LCD screen
  • Flow-cell and cuvette mode possible
  • Internal thermal printer
  • Test modes: Single and double wavelength
  • Temperature control: RT, 25°C, 30°C, 37°C ± 0.1°C
  • Language: English or Spanish
  • Real-time-reaction curve display
  • Equipped with USB mouse and built-in keyboard
  • Windows ® based operating system
  • Endpoint with or without reagent blank or sample blank
  • Bichromatic endpoint (double wavelength)
  • Kinetic
  • Fixed time (two point kinetic)
  • Linear regression
  • Absorbance
  • Multi-calibration curve
  • Wavelengths: 300 – 800 nm
  • 7 standard filters: 340, 405, 450, 500, 546, 578, 670 nm
  • 1 free position for optional filter
  • Absorbance range: -0.500 – 3.500 Abs
  • Resolution: 0.001 Abs displayed; 0.0001 calculated
  • Light source: Halogen lamp
  • Test memory: up to 110 methods programmable, 1000 test results
  • QC functions: Westgard Multirule, Levey Jennings plot, 2 controls per test
  • RS-232 for LIS
  • 2x USB: Mouse and ext. keyboard or ext. printer (not included)
  • Power supply: 110/230 VAC, 50/60 Hz, 80 Watt
  • Net weight: 8 kg
  • Gross weight: 9.5 kg
  • Dimensions: 350 x 330 x 165 mm (H x W x D)

Photometer DTN-405

Photometer DTN-405
  • Color LCD screen
  • Flow-cell and cuvette mode possible
  • Internal thermal printer
  • Test modes: Single and double wavelength
  • Temperature control: RT, 25°C, 30°C, 37°C ± 0.1°C
  • Language: English or Spanish
  • Real-time-reaction curve display
  • Endpoint with or without reagent blank or sample blank
  • Bichromatic endpoint (double wavelength)
  • Kinetic
  • Fixed time (two point kinetic)
  • Linear regression
  • Absorbance
  • Multi-calibration curve
  • Wavelengths: 300 – 800 nm
  • 5 standard filters: 340, 405, 505, 546, 578 nm
  • 3 free position for optional filter
  • Absorbance range: -0.500 – 3.500 Abs
  • Resolution: 0.001 Abs displayed; 0.0001 calculated
  • Light source: Halogen lamp
  • Test memory: up to 60 methods programmable, 1000 test results
  • QC functions: Control report
  • RS-232 bidirectional communication
  • SPP (Standard Parallel Port) for external Printer
  • Power supply: 110/230 VAC, 50/60 Hz, 80 Watt
  • Net weight: 7 kg
  • Gross weight: 8.5 kg
  • Dimension: 360 x 318 x 160 mm (H x W x D)

Autolyser 250

  • Throughput up to 250 tests/hour
  • Operating mode: Random access
  • Test modes: Routine, Batch, STAT, Profiles
  • Up to 500 tests in memory
  • Sample / calibrator pre-dillution
  • Cooled reagent tray
  • Cuvette washing station
  • Solid state photometer with 10 channels 340 – 700nm
  • Long life ceramic dilutor
  • Crash sensor
  • QC program
  • Patient archive
  • Operating by external PC (not included)
  • Non disposable  optical glass cuvettes
  • Optional barcode reader for samples and reagents
  • Liquid tanks for water system and waste water
  • Biderectional LIS
  • Systempacks available
  • Approximately 5ml / test
  • USB Port
  • Power supply: 110/230 VAC, 50/60 Hz, 80 Watt
  • Net weight: 7 kg
  • Gross weight: 8.5 kg
  • Dimension: 360 x 318 x 160 mm (H x W x D)

Autolyser 450

  • Throughput up to 450 tests/h without I.S.E (up to 690 tests/h with I.S.E)
  • Optional with I.S.E module (Na, K, Cl, Li)
  • Test modes: Routine, Batch, Emergencies (STAT), Profiles
  • Up to 500 tests in memory+ unlimited relation tests
  • Sample: Serum, Urine, Plasma, CSF
  • Sample & Calibrator pre-dilution
  • Cooled reagent tray
  • Cooled calibrator & control tray
  • Non disposable optical glass cuvettes
  • Solid state photometer with 14 channels 340-800nm
  • Clot sensor
  • Crash sensor
  • QC program
  • Internal barcode reader for sample and reagents
  • Bidirectional LIS
  • No existing water and waste lines necessary
  • Reagent tray: 80 positions, cooled
  • Sample tray: 100 positions
  • Calibrator & control tray: 26 positions, cooled
  • Reaction tray: 84 glas cuvettes, heated
  • Sample volume: 1.5 μL to 100 μL
  • Reaction volume: 180 μL to 400 μL
  • Cuvette temperature: OFF/37°C ± 0.2°C (Peltier controlled)
  • Solid state photometer: 14 channel + 1 ref. channel
  • Wavelengths: 340, 380, 405, 436, 478, 510, 546, 578, 600, 630, 660, 700, 740, 800 nm
  • Absorbance range: 0.000 – 3.000 Abs
  • Sensitivity: ± 0.001 Abs
  • Accuracy: ± 1% from 0 to 2.000 O.D
  • Tungsten halogen lamp with dichroic reflector
  • Lamp Life time approximately 2000 hours
  • 1x Sample pipetting arm
  • 2x Reagents pipetting arms
  • 3x Long life ceramic dilutors
  • Dilutor precision: ± 0.1 %
  • Dilutor resolution ± 0.1 μL for serum
  • ± 1.0 μL for reagents
  • Power supply: 100 / 240 VAC, 50-60 Hz, 550 Watt
  • U.P.S.: 1500 Watt
  • Net weight: 162 kg
  • Gross weight: 237 kg
  • Dimensions: 1150 x 1150 x 720 mm (H x W x D)