Automated Elisa System

DIALISA 2MP

Dialisa 2MP
  • Smallest footprint on the market for a fully automated 8 pin wash head ELISA system
  • Learned error recovery: Supporting walk-away automation with trained error recovery actions
  • LIS and LIMS compatible
  • QC monitoring
  • Sample identification with an optional on-board barcode reader
  • Compatible with DIALAB® ELISA assays
  • No. of plates: 2
  • No. of assays: 1 assay per strip or up to 12 assays/plate
  • No. of samples: 100
  • No. of reagents: 18
  • No. of Std/Ctrl: 24
  • No. of pipettes: 1
  • Reader
  • Washer
  • Incubator
  • Sample module
  • Ambient drawer
  • Barcode reader (optional)
  • Liquid tanks for system- and waste water
  • Sample tip size: 300 μLSample pipetting volume: 10 – 250 μL
  • Precision: ≤ 3% CV (10 – 250 μL)
  • Dilution range: 1 to 5000
  • Replicates: Up to 96 samples, standards and controls
  • Number of sample-tips: 2 racks of 108
  • Sample tube dimensions: 10 – 16 mm Ø, 40 -100 mm length
  • Reagent tip size: 1300 μL
  • Number of reagent tips: 20
  • Reagent pipetting volume: 20 – 1000 μL
  • Reagent pipetting precision: ≤ 3% CV (10 – 1000 μL)
  • Manifold configuration: 8 – way
  • Programmable volumes: 50 – 1000 μL
  • Wash containers: 2 wash bottles at 2.0 L, with level-sensing
  • Waste containers: 1.5 L with waste-full sensor
  • Residual wash volume: < 3 μL
  • Number of incubators: 1
  • Temperature range: RT, 4° C to 40° C
  • Temperature accuracy: ± 1° C
  • Shaking: 14-20 Hz periodic or continuous
  • Photometric range: 0.000 – 3.000 OD
  • Spectral range: 405 nm – 690 nm
  • Filter: 405 nm, 450 nm, 490 nm, 620 nm
  • Precision: < 1% CV (< 2.000 OD); < 2% CV (2.000 – 3.000 OD)
  • Accuracy: 0.005 OD or 2.5%
  • Reading time: < 30 seconds, single wavelength
  • Power supply: 100 – 240 VAC, 50/60 Hz
  • Power consumption: < 300 VA, UPS recommended
  • Net weight: 45 kg
  • Gross weight: 80 kg
  • Dimension: 660 x 540 x 680 mm (H x W x D)

DIALISA 4MP

  • Modular system: Quick and easy approach for upgrades, repairs and reconfiguration of the whole system
  • Rapid pipetting speed minimises assay drift, ensuring consistent results across the plate and plate-to-plate
  • Learned error recovery: Supporting walk-away automation with trained error recovery actions
  • Automatic cover lock protecting reagents and samples from light and interferences
  • LIS and LIMS compatible
  • QC monitoring
  • Sample identification with an optional on-board barcode reader
  • Disposable tips eliminating carryovers
  • Compatible with DIALAB® ELISA assays

 

  • No. of plates: 4
  • No. of assays: 1 assay per strip or up to 12 assays/plate
  • No. of samples: 96
  • No. of reagents: 24
  • No. of Std/Ctrl: 33
  • No. of pipettes: 1
  • Reader
  • Washer
  • Incubators (Up to four)
  • Sample module
  • Ambient drawer
  • Barcode reader (Optional)
  • Liquid tanks for system – and waste water
  • Sample tip size: 300 μL
  • Sample pipetting volume: 5 – 250 μL; 5 – 250 μL single-shot; 25 – 100 μL multi-shot
  • Precision single-shot: ≤ 3% CV at operating volume above 10 μL
  • Accuracy single-shot: ± 2% of target volume at any operating volume above 10 μL
  • Dilution range: 1 part in 190 one-stage dilution; 1 part in 36100 two-stage dilution
  • Number of sample-tips: 4 racks of 108 tips
  • Sample tube dimensions: 12 – 16 mm Ø external dimension; 55 – 100 mm length
  • Reagent tip size: 1300 μL
  • Number of reagent tips: 41
  • Reagent pipetting volume: 35 – 1000 μL
  • Reagent pipetting precision: ≤ 3% CV at 10 shots at any volume in operating range above 25 μL
  • Reagent pipetting accuracy: ± 2% of target volume in operating range (singe-shot mode)
  • Manifold configuration: 8 – way
  • Programmable volumes: 50 – 999 μL
  • Wash containers: 4 wash bottles at 2.0 L with level-sensing
  • Waste containers: 8.0 L with waste-full sensor
  • Residual wash volume: < 3 μL per well with dual-axis sweep in a flat-bottom plate
  • Dispense precision: ≤ 5% CV (with 300 μL in a 96 well plate)
  • Number of incubators: Up to 4
  • Temperature range: RT, 7° C to 50° C
  • Temperature accuracy: ± 1° C
  • Shaking: > 15 Hz periodic or continuous
  • Photometric range: 0.000 – 3.000 OD
  • Spectral range: 405 nm – 690 nm
  • Filter: 405 nm, 450 nm, 490 nm, 620 nm
  • Precision: ± 0.01 OD at 0.000 – 0.500 OD; < 1% CV at 0.501 – 2.000 OD; < 1.5% CV at 2.001 – 2.500 OD
  • Accuracy: ± 0.01 OD or 2.5% (0.000 – 3.000 OD)
  • Reading time: < 10 seconds, single wavelength; < 20 seconds, dual wavelength
  • Power supply: 100 – 240 VAC, 50/60 Hz
  • Power consumption: 800 VA, UPS recommended
  • Net weight: 136 kg
  • Gross weight: 244 kg
  • Device: 830 x 1030 x 900 mm (H x W x D)