Coagulation Analyzers

DIAcheck C1
  • Upgraded Hardware & Software

  • Clotting, chromogenic or immunoturbidimetric assay

  • Quarter method (75µl sample and reagent volume)

  • Auto start function

  • Maintenance free

  • Closed system cuvettes

  • Coloured Touchscreen

  • Optic cell: Photometer with pulsed 620 nm LEDs
  • Calibration points: 3
  • Methods: PT, FIB, APTT, TT, D-Dimer
  • Sample: Plasma
  • Result conversion: Seconds, INR, %, Ratio, Units (mg/dL, g/L, ng/mL)
  • Incubation block: Measuring positions: 1 x 1 /
  • Sample positions: 10 x 1 / Reagent positions: 5
  • Incubation temp.: 37.0°C ± 0.2°C
  • Language: English, others on request
  • External Printer: optional
  • Barcode reader: optional
  • Interface: 2x RS232, 2 x USB
  • Power: 100-240 VAC, 50-60 Hz
  • LIS compatible: Yes
  • Power supply: Input: 100-240 VAC, 50-60 Hz, Output: 5 VDC, 3.3 A
  • Weight: 1.04 kg
  • Dimensions: 225 x 150 x 90 mm (W x D x H)

DIAcheck C2

  • Clotting, chromogenic or immunoturbidimetric assays

  • Quarter method
    Auto-start function

  • Maintainance free

  • Optic cell: Photometer with pulsed 405 nm LEDs
  • Calibration points: 5
  • Methods: PT, APTT, FIB, TT, AT, DD, PC, Factors (II, V, VII, VIII, IX, X, XI, XII), AF2, AF10, HEP, LMH, APIX, RIVX, EDOX, DABI
  • Sample: Plasma
  • Result conversion: Seconds, INR, %, Ratio, Units (mg/dL, g/L, ng/mL)
    Incubation block: Measuring positions: 2 / Sample positions: 20 / Reagent positions: 5
  • Incubation temp.: 37.0°C ± 0.2°C
  • Language: English, German, French, Spanish, Italian
  • External Printer: optional
  • Barcode reader: optional (internal or external)
  • Interface: 2 x RS232, 2 x USB
  • LIS compatible: Yes
  • Power supply: 100-240 VAC, 47-63 Hz
  • Weight: 1.04 kg (without power supply)
  • Dimensions: 225 x 150 x 90 mm (W x D x H)

DIAcheck C4

  • Clotting, chromogenic or immunoturbidimetric assays

  • Quarter method

  • Auto-start function

  • Maintainance free

  • Optic cell: Photometer with pulsed 405 nm LEDs
  • Calibration points: 5
  • Methods: PT, APTT, FIB, TT, AT, DD, PC, Factors (II, V, VII, VIII, IX, X, XI, XII), AF2, AF10, HEP, LMH, APIX, RIVX, EDOX, DABI
  • Sample: Plasma
  • Result conversion: Seconds, INR, %, Ratio, Units (mg/dL, g/L, ng/mL)
    Incubation block: Measuring positions:  4 / Sample positions: 20 / Reagent positions: 5
  • Incubation temp.: 37.0°C ± 0.2°C
  • Language: English, German, French, Spanish, Italian
  • External Printer: optional
  • Barcode reader: optional (internal or external)
  • Interface: 2 x RS232, 2 x USB
  • LIS compatible: Yes
  • Power supply: 100-240 VAC, 47-63 Hz
  • Weight: 1.04 kg (without power supply)
  • Dimensions: 225 x 150 x 90 mm (W x D x H)

Coalyser

Coalyser
  • Clotting and immunoturbidimetric assays

  • Throughput: PT 137 tests/hour, APTT 60 tests/hour ± 20 tests/hour

  • Micro method

  • STAT program

  • QC program

  • Bidirectional LIS

  • Continuous loading of samples
    Internal sample barcode reader
    Color touch display 17.0 x 12.5 cm

  • TFT

  • ChipCARDTM for cuvette management

  • Calibration points: Up to 7 calibration points, 2 calibration curves per test or automatic calibration
  • LIS compatible: Yes
  • Measuring principle: Photometric, 2-channel LED photometer with 2 reference channels, Wavelengths: 450 nm, 570 nm, 740 nm
  • Temp. controlled measuring unit: 37.0°C ± 0.4°C
  • Sample: Plasma
  • Result conversion: Seconds, INR, %, Ratio, Units (mg/dL, g/L)
  • Cuvettes: Disposable cuvette ring with 32 cuvettes
  • Sample positions: 2x 11 positions
  • STAT positions: 3 positions
  • Reagent positions: 15 positions (3x 15 mL, 12x 5 mL), 3 of them stirred
  • Cal & Ctrl positions: 8 positions
  • Pipettor washing station: Yes
  • Sampling: Capacitive pipettor heated at 37 °C
  • Dilutor: 2 – 250 µL (precise in 1 µL steps)
  • Language: English, German, Russian, Spanish
  • Printer: External
  • Interface: 2x RS232C, 2x USB, LAN & ChipCARD™ reader
  • Methods: PT, Factors (II-XII), Factors V Leiden, D-Dimer, Protein C&S, Ecarin, FIB, PT/FIB, BT, TDT, APTT, PiCT, TT, AT III. Up to 50 methods programmable
  • Power supply: 100/240 VAC, 50-60 Hz, 300VA
  • Net weight: 25.0 kg
  • Gross weight:  30.0 kg
  • Dimensions: 500 x 780 x 580 mm (H x W x D)